FAQ
FREQUENTLY
ASKED
QUESTIONS.
Here you will find frequently asked questions about AEROSEAL®.
1. WHAT IS AEROSEAL®
AEROSEAL® is an innovative sealing process that seals leaking ventilation systems from the inside. It improves energy efficiency and indoor air quality by effectively eliminating leaks.
2. HOW DOES THE AEROSEAL® PROCESS WORK?
A special sealant is blown into the ventilation system as a fine mist. The particles settle at the leak sites and form a flexible, durable seal.
3. For which ventilation systems is AEROSEAL® suitable?
The process is suitable for residential buildings, commercial properties, industrial facilities, and medical facilities with ventilation or air conditioning systems.
4. WHAT IS THE MAXIMUM ALLOWABLE LEAKAGE?
The AEROSEAL® process can be used to seal gaps with a maximum width of 15 mm. For larger areas, it is not possible to guarantee that the leak will be completely sealed. Larger areas should be sealed manually.
5. IS THE INSIDE COATED WITH SEALANT?
No! The sealant was designed to adhere only to leaks.
6. HOW LONG DOES THE PROCESS TAKE?
The sealing work usually takes 3–8 hours, depending on the size and condition of the system.
7. DO ENVIRONMENTAL FACTORS AFFECT SEALING?
To achieve optimum results when sealing with MEZ-AEROSEAL, the humidity should not exceed 50–60%. However, if this is not possible due to the circumstances, it is recommended to heat the intake air upstream of the equipment using a heater to reduce the humidity.
8. WHAT NEEDS TO BE TAKEN INTO ACCOUNT WHEN SEALING IN ENCLOSED SPACES?
When sealing in enclosed spaces, all smoke and fire detectors and sprinkler systems should be switched off beforehand, as these could be triggered during the sealing process.
9. Which components should be removed beforehand?
Before sealing, sensors or measuring crosses that measure the volume flow should be removed, as the functionality of these components could be affected by the sealing. Components such as blinds or fire dampers do not need to be removed from the duct network before sealing with MEZ-AEROSEAL. Only the dampers should be open so that the sealant can pass through them without any problems.
10. HOW LONG DOES THE SEAL LAST?
The seal has a 10-year warranty. However, seals generally have a service life of more than 30 years.
11. IS AEROSEAL® SEALANT SAFE FOR HEALTH?
Yes, the sealant consists of non-toxic, water-based polymer particles that are also used in chewing gum and medical products.
12. HOW MUCH ENERGY CAN BE SAVED WITH AEROSEAL®?
With AEROSEAL® as the basis for further optimizations, energy costs can be reduced by 30-50%.
13. HOW MUCH DOES AN AEROSEAL® SEAL COST?
The costs depend on the size and condition of the ventilation system. As a rule, the investment costs are recouped within a few years through the energy savings. The ROI is usually 3-5 years.
14. ARE THERE ANY SUBSIDIES AVAILABLE FOR AEROSEAL®?
Yes, many countries offer subsidy programs for energy-efficient building technology. It is worth checking with local authorities to see what subsidies are available.
15. CAN YOU EXPERIENCE AEROSEAL® LIVE IN ADVANCE?
Yes! We would be happy to demonstrate the process to you in our DEMO AREA in Reutlingen, Baden-Württemberg. Simply contact us to arrange an appointment.
Mit Hilfe von MEZ-AEROSEAL können Leckagen mit einer maximalen Breite von 1,5 cm abgedichtet werden. Bei einer größeren Fläche kann nicht mehr sichergestellt werden, dass die Leckage komplett verschlossen wird. Größeren Flächen sollten manuell verschlossen werden.
Ja! Bei einer Vielzahl von Krankenhäusern auf der ganzen Welt, führte die Anwendung von MEZ-AEROSEAL zu einer Verbesserung der Raumluftqualität (IAQ). Des Weiteren wurden Belästigungen, verursacht durch Gerüche, sowie die Verbreitung von Keimen eliminiert. Klicken Sie hier und lesen Sie unsere Fallstudien aus dem Bereich "Medizin"
Nein! Der Dichtstoff wurde so konzipiert, dass er nur an Leckagen haften bleibt.
Um ein optimales Ergebnis bei der Abdichtung mit MEZ-AEROSEAL zu erreichen sollte die Luftfeuchtigkeit nicht über 50 - 60% liegen. Sollte dies jedoch aufgrund der Gegebenheiten nicht möglich sein, empfiehlt es sich die Ansaugluft vor dem Equipment mittels Heizwärmer zu erhitzen und die Luftfeuchtigkeit dadurch zu reduzieren..
Beim Abdichten in geschlossenen Räumen sollten alle Rauch- und Feuermelder sowie Sprinkleranlagen vorher abgeschaltet werden, da diese beim Abdichtungsvorgang anspringen könnten.
Vor dem Abdichten sollten beispielsweise Sensoren oder Messkreuze, welche den Volumenstrom messen, entfernt werden, da die Funktionalität dieser Bauteile durch das Abdichten beeinflusst werden könnte. Bauteile wie Jalousie- oder Brandschutzklappen müssen vor dem Abdichten mit MEZ-AEROSEAL nicht aus dem Kanalnetz entfernt werden. Lediglich die Klappen sollten geöffnet sein, damit der Dichtstoff hier problemlos seinen Weg hindurch findet.
Auf die Abdichtung gibt es eine Garantie von 5 Jahren. In der Regel haben die Abdichtungen jedoch eine Lebensdauer von mehr als 40 Jahren.
Ja! Melden Sie sich hierfür einfach für einen unsere MEZ-Aeroseal Demo Days an. Nehmen Sie hierfür einfach Kontakt zu uns auf